Formatting and partitioning – Dulce Systems PRO FC g2 User Manual
Page 14
Page 27
PRO FC
g2
Installation and User’s Manual
6.1.
Replacing a Disk Module
A defective Disk Module can be easily replaced. Hot swapping is allowed without
interruption to your workflow if the RAID is operating in one of the drive
redundant RAID mode (1,5,6).
In a redundant RAID mode, rebuild will start automatically after replacement of a
defective module.
• Pull the Lock Pin to the right and pull the Disk Module out.
The RAID rebuild will consume some processing power from the overall
operation speed of the PRO FC, the rebuild can be suspended during time
sensitive operations.
From RAID Manager, click on RAID > Modify. Select the RAID on the left side,
then click on Stop Rebuild at the lower right.
The audible alarm will sound, follow the Alarm Condition / Mute Alarm to handle
it.
Page 28
PRO FC
g2
Installation and User’s Manual
7. Formatting and Partitioning
7.1.
Apple OS X Formatting
The PRO FC are shipped pre
appear on the desktop after driver installation and reboot.
Should it be necessary to re
Apple Disk Utility.
To start Disk Utility, move pointer to upper left corner of screen, click on Go then
click on Utilities. Locate and launch Disk Utility.
7.1.1. Erase an existing partition
Select the RAID on left, click on Partition tab, select Free Space. Click on
Partition on lower right.
Installation and User’s Manual
Formatting and Partitioning
Formatting
are shipped pre-configured for Mac OS X, the RAID will
appear on the desktop after driver installation and reboot.
Should it be necessary to re-format and partition the RAID, use the
To start Disk Utility, move pointer to upper left corner of screen, click on Go then
ocate and launch Disk Utility.
existing partition
Select the RAID on left, click on Partition tab, select Free Space. Click on
X, the RAID will
To start Disk Utility, move pointer to upper left corner of screen, click on Go then