639513_pg 2, Controller program startup and device scan – CommScope ATC200-1000 User Manual
Page 3
Pre-Installation Notes:
•
Connect the local PC to the controller using the Ethernet crossover cable.
•
Before installing antennas equipped with actuators to the tower, each actuator
should be connected to the controller and tested for proper operation.
•
Andrew recommends that you register online to receive notif cations for up-
dates made to the software and antenna def nition f le. It is also recom-
mended that the Commscope web site be checked every 30 days for updated
software/documentation.
•
If using the 48V power connection, ensure wires are properly connected.
Reversal of wire connection can cause permanent damage to the
controller.
2. Controller program startup and device scan
•
Click on Go (or press Enter on the keyboard) to access
the ATC200-1000
Controller main interface screen (below).
2. Device search. Click on Find Devices.
See screen above.
•
Select number of known devices on Max devices drop down list, below.
•
Click on Start Scan, as seen on screen below.
•
After the scan is complete, click on Close.
•
If an antenna/actuator has been removed or added to the site, a new
scan is required.
1. Controller access.
•
Refer to Bulletin 639561 for instructions about using the IP Conf g Tool to
reconf gure the local PC/laptop’s IP address for access to the ATC200-
1000’s main operating interface.
•
Type the controller’s IP address into Internet browser URL window. The
factory default IP address is 192.168.255.141. See screen below.