Rapid flow installation – Bully Dog 82202 Rapid Flow User Manual
Page 5

4
rAPid FlOW inSTAllATiOn
rapid Flow exhaust # 82400,82202
Important: It is illegal in all 50 states and Canada to remove the catalytic converter.
REMOVAL OF STOCk EXHAUST SySTEM
In these steps you will remove the stock exhaust system.
1.Use a sawzall to cut the exhaust directly behind
the muffler.
2. Cut the Straight Pipe in front of
the muffler.
3. Cut the stock Down Pipe just after the bend.
4.Cut behind the Catalytic Converter and in front
of it .
5. Loosen the stock band clamp us-
ing a 7/16” deep socket where the
stock down pipe is connected to
the turbo. The stock band clamp
will be used later so don’t remove
it, just loosen it enough to remove the stock
down pipe.
6. To make removing the Hangers an easier pro-
cess it is recommended that you
use a silicone spray lubricant to
spray each of the rubber hangers
holding the stock exhaust.
7. Remove each
piece of the stock
exhaust
system,
including the stock
exhaust hangers.
Cut directly in front of the Muffler
Cut 4” behind the Catalytic Converter
Remove all the necessary exhaust hangers
Loosen stock band clamp
7/16”