Technical specifications
Type
Constant current and voltage control system with timer
interventions
CC-MODE: Output current
4900mA ± 1%
CC-MODE: Vmax
16800 ± 50mV (0.3%)
CV-MODE: Vmax
16800 ± 50mV (0.3%)
CV-MODE: Cutoff current
150mA ± 10mA
Short circuit protection
Available
Overcharge protection
Available
Overtemperature protection
Available
LEDS
3 colour type for BAT1~BAT8 and AUX
LCD
2x 20x4 Blue/White backlight
Special features
IPCS and CTP
Auxiliary power
2x 13.8V 110W (max)
Power supply
AC mains 100V - 240V ~, 47 - 63 Hz autoselect
Fuse
1 x 220V 2.5A (5x20mm quick blow) + 1 spare
Power consumption
200W max / 180W typical
Operating temperature range
0°C - 45°C
Storage temperature range
-20°C - 65°C (-4°F - 149°F)
Dimensions
620 x 410 x 110 mm
Weight
9.7 Kg