3. SETUP

Connecting A Bunch of Motif Fresco™ Fixtures

You will need a serial data link to run light shows using a DMX-512

controller or to run shows on two or more fixtures set to sync in

master/slave operating mode. The combined number of channels

required by all the fixtures on a serial data link determines the number

of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line.

Also, connecting more than 32 fixtures on one serial data link without

the use of a DMX optically-isolated splitter may result in deterioration

of the digital DMX signal. The maximum recommended cable-run

distance is 500 meters (1640 ft). The maximum recommended

number of fixtures on a serial data link is 32 fixtures.

Data / DMX Cabling

To get a DMX signal into (or out to) standard 3-pin DMX cable, a

Blizzard DMX adapter cable set (CABLE Motif DMX SET) must be used

to convert the standard DMX plug to mini DMX plug (or vice versa).

And when linking between any Motif Series units, a 3-meter mini DMX

extension is available if nessecary for your application (CABLE Motif

Data3M). Both of these items are sold separately. Please contact your

authorized Blizzard Lighting dealer to order either of these items.

All of your data cables should be a high-grade cable that can carry a

strong signal, making them less prone to electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-

485 applications. Standard microphone cables will “probably” be

OK, but note that they cannot transmit DMX data as reliably over

long distances. In any event, the cable should have the following

characteristics:

2-conductor twisted pair plus a shield

Maximum capacitance between conductors – 30 pF/ft.

Maximum capacitance between conductor & shield – 55 pF/ft.

Maximum resistance of 20 ohms / 1000 ft.

Nominal impedance 100 – 140 ohms