Introduction

This instruction book is intended for use by operators and in-

stallers of the Model 8072A-1 and 8072A-2 load resistor.

Description

The Bird Model 8072A-1 and 8072A-2 Termaline Coaxial

Load Resistor is a dry (air dielectric), conduction cooled

(needs heat sink), type 50-ohm RF (Radio Frequency) line

termination. It is capable of dissipating 300 W of continuous

power when properly mounted to a suitable heat sink. The

load is designed for a reflection-free termination of a trans-

mission line and is efficient in any position. The Model

8072A-1 and 8072A-2 is normally supplied with an N-Type

Female connector.

Installation

Unpacking

and

Inspection

All packages are carefully inspected prior to shipment. If

package shows any sign of damage, promptly inspect the de-

vice. If any damage is visible, notify the shipping carrier and

Bird Electronic of the damage.

Retain the shipping materials for repackaging.

Connections

A suitable heat sink is required. It must be of such capacity

that at 300 W of continuous input, the temperature on top of

the load body will not exceed 155°C (311°F). Use an alumi-

num plate of at least 800 sq. in. by 1/8 in. thick (5200cm

² x

3mm) or equivalent.

Attach the load to a suitable heat sink as follows:

1. Apply a thin film of heat transfer compound over

the entire mating surface.

+

NOTE: The film, when flattened, must not ex-

ceed a thickness of 0.001 inch.

2. Mount the load to the heat sink using six mount-

ing screws, preferably stainless steel, and of suit-

able length to include the 1-1/32 inch load body,

heat sink thickness, washer and nut.