Bird 8930 Series Semiconductor Termaline Coaxial Load Resistor

8

AC Power

Connection

The ac power supply required for this unit is 115/230 V, depending on
the model, @ 50/60 Hz, 1

φ

. The blower is equipped with an IEC 320

“cold” (65

°

C) ac inlet.

Connecting RF

Power

After installing the load, the RF transmission line can be attached
using standard coaxial line coupling kits.

“QC” Connector Coupling:

Use 50 ohm coaxial cable such as

RG-218/U or -220/U (-17A or -19A), appropriate for the frequency and
power level of operation. Use a cable connector which will mate with
the one on the load.

CAUTION

Check the local electrical code for proper ac hookup prior to

operation of the unit. Make sure the neutral or return hookup is

only used for that purpose.

WARNING

Turn off ac power and RF power when attaching the power cable.

WARNING

Never attempt to connect or disconnect RF equipment from the

transmission line while RF power is being applied.

Leaking RF energy is a potential health hazard.