Fault Isolation Procedures

2-45

Code 16 (SID 11, FMI 2) Left Side Sensor, continued

Step C

Procedure

Condition

Action

1. Key off.

2. Disconnect Central Processing

Unit 32-way connector.

3. Measure resistance between:

• 32-way pin D12

and 3-way pin C.

• 32-way pin D12

and ground.

If resistance between D12
and pin C is 0 to 0.3 ohms
and if resistance between
pin D12 and ground is more
than 10K ohms or open
circuit [OL]

If resistance is out of range

Go to Step D.

Repair OEM wiring harness
between Left Side Sensor and
Central Processing Unit.
Go to Step V.