Baumfolder Flexifold: Pile Folder (in 2004) User Manual
Page 27

PAGE 27
TP10496
A. Pile Height Sensor Sensitvity
Adjustment - This adjustment is made by turning
the pot located on top of the sensor next to the
indicator. This will increase or decrease the
sensitivity of the sensor.
Note: Do not turn the pot adjustment past it stops.
Damage to the sensor may result.
B. Pile Height Vertical Location
Adjustment - This adjust can be made by loosening
the locking lever holding the sensor in place. The
sensor will now be free to move vertically in its
retainer. Tighten the locking lever to lock the
sensor in place. Only tighten the locking lever so
much that it holds the sensor in place. Do not over
tighten the locking lever, as this could damage the
sensor.
This height is adjusted at the factory so that
it is 1/2” (38.10mm) above the paper stack.
C. Pile Height Sensor Plastic Ring- This
plastic donut prevents the sensor from detecting
objects such as side guides. It may be necessary to
lower or raise this ring by looseing the set screw
holding it in place, depending on the location of
the side guides.
Sensitivity
Adjustment
Plastic Ring
Locking Lever
Indicator
LANGUAGE SELECTION
Dip switches found on the CPU Board
ENGLISH
GERMAN
SPANISH
FRENCH
220 VOLT
ENGLISH
GERMAN
SPANISH
FRENCH
115 VOLT