Basic Installation and Configuration Guidelines for Mach 3
EL-Series Spa Controllers.

Use minimum 6AWG copper conductors only.

Torque field connections between 21 and 23 in lbs.

Readily accessible disconnecting means to be provided at
time of installation.

Permanently connected.

Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) mounted at least 5’ (1.52M) from the
inside walls of the spa/hot tub and in line of sight from the
equipment compartment.

CSA enclosure: Type 2

Typical field connections
for main power.

Refer to Wiring Diagram
inside the cover of the
control enclosure.

Refer to Installation and
Safety Instructions provided
by the spa manufacturer.

Warning:

People with infectious diseases should not use a

spa or hot tub.

Warning:

To avoid injury, exercise care when entering or

exiting the spa or hot tub.

Warning:

Do not use a spa or hot tub immediately following

strenuous exercise

Warning:

Prolonged immersion in a spa or hot tub may be

injurious to your health

Caution:

Maintain water chemistry in accordance with the

Manufacturers instructions.

Caution:

The equipment and controls shall be located not

less than 1.5 meters horizontally from the spa or hot tub.

CSA Compliance/Conformité
Caution:

• Test the ground fault circuit interrupter before each use of

the spa.

• Read the instruction manual.
• Adequate drainage must be provided if the equipment is to

be installed in a pit.

• For use only within an enclosure rated CSA Enclosure 3.
• Connect only to a circuit protected by a Class A ground

fault circuit interrupter.

• To ensure continued protection against shock hazard, use

only identical replacement parts when servicing.

• Install a suitably rated suction guard to match the

maximum flow rate marked.

Warning:

• Water temperature in excess of 38°C may be injurious to

your health.

• Disconnect the electrical power before servicing.

Attention:

• Toujours verifier l’efficacite du disjoncteur differentiel avant

d’utiliser differentiel avant d’utiliser le bain.

• Lire la notice technique.
• Lorsque l’appareillage est installe dans une fosse, on doit

assurer un drainage adequat.

• Employer uniquement a l’interieur d’une cloture CSA

Enclosure 3.

• Connecter uniquement a un circuit protege par un

disjoncteur differentiel de Class A.

• Afin d’assurer une protection permanente contre le danger

de shock electrique, lors de l’entretien employer seulement
des pieces de rechange identiques.

• Les prises d’aspiration doivent etre equipees de grilles

convenant au debit maximal indique.

Avertissement:

• Des temperatures de l’eau superieures a 38°C peuvent

presenter un danger pour la sante.

• Deconnecter du circuit d’alimentation electrique

avante l’entretien.

Warning/Advertissement:

• Disconnect the electric power before servicing. Keep access

door closed.

• Deconnecter du circuit d’alimentation electrique avant

l’entretien. Garder la porte fermer.

GREEN

WHITE

WHITE AC (120 V)

FOR W-WIRES

RED AC (240 V)

FOR W-WIRES

BLACK

RED

FROM GFCI

J23 J19 J28
J43 J42 J48

J53 J54
J55 J25
J26

Warning! GFCI Protection.

The Owner should test and reset the GFCI on a regular
basis to verify its function.

Warning!

Qualified technician required for service and installation.