TROUBLESHOOTING (cont.)

PROBABLE CAUSE

REMEDY

PROBLEM

Product level in ULTRA is lower than
level Probe - ULTRA running; Pow-
der Auto-Fill door lamp flashes two
times

Product level in ULTRA is lower than
level Probe - ULTRA running; Pow-
der Auto-Fill door lamp flashes three
times

Product level in ULTRA is lower than
level Probe - ULTRA running; Pow-
der Auto-Fill door lamp flashes four
times

The ULTRA product tastes "watery"
or "sugary"

Powder Auto-Fill dispenses dry prod-
uct only - dry powder build-up in
mixing and whipper chambers

1. Powder Auto-Fill not pulled com-
pletely forward.

2. ULTRA level probe misaligned.

1. Powder Auto-Fill hopper not in-
stalled properly.

1. Refill time exceeded five minutes.

1. Improper adjustment of product
mix ratio.

1. Powder Auto-Fill not connected to
water source.

2. Water source turned off.

3. Water line obstructed.

1. Check that the Powder Auto-Fill is
pulled completely forward until the
guide rails roll into the indented po-
sition.

2. Position the ULTRA level probe so
that it is located in the notch of the
ULTRA hopper and touching the con-
tact protruding from the front of the
PAF platform.

1. Properly position the Powder
Auto-Fill hopper.

.

Check that the SERVICE switch is
released or reset by opening and
closing the Powder Auto-Fill door.

Adjust the product mix ratio per in-
structions in Powder Auto-Fill Ad-
justment. See page 5.

1. Connect the Powder Auto-Fill to a
20 to 90 psi (138 to 620 kPa)water
source.

2. Turn water source on.

3. Remove obstruction.

29793.1 021202