beautypg.com

Bunn dispenser User Manual

Page 8

background image

8

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the dispenser when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices

PROBLEM

PROBABLE CAUSE

REMEDY

ULTRA and Powder Auto-Fill do not
run - Main power on ULTRA is OFF

Product level in ULTRA is lower than
level Probe - ULTRA running; Pow-
der Auto-Fill door lamp is OFF

Product level in ULTRA is lower than
level Probe - ULTRA running; Pow-
der Auto-Fill door lamp flashes ON
and OFF

1. ULTRA power cord disconnected
or main power switch in ON posi-
tion.

1. The ULTRA DAY/NIGHT setting is
in the NIGHT mode.

2. Powder Auto-Fill power cord dis-
connected.

3. Powder Auto-Fill main power
switch in OFF position.

5. Powder Auto-Fill door is open.

1. Low product in Powder Auto-Fill.

Check that the power cord is con-
nected to proper electrical source
and that the ULTRA main power
switch is in the ON position.

1. The ULTRA DAY/NIGHT setting
should be in the DAY mode.

2. Check that the Powder Auto-Fill is
plugged into the top of the ULTRA
auger motor cover.

3. Select the ON position of the main
power switch.

5. The Powder Auto-Fill door should
be closed securely.

Remove hopper and fill with pow-
dered mix.

29793.1 021202