Pre-Installation Information
Texas Accessibility Standards compliant:
The SS-3/AST/WH97TAS Express® Lavatory System meets Texas Accessibility standards
(TAS) for barrier-free clearances, reaches and controls. Always check local codes and ordinances
for compliance.
Pushbutton and air valve
Each sprayhead is controlled by a pushbutton air valve, enabling each user to activate a single flow
of water. Air valves use 0.5 gpm for a ten-second duration, meeting the ANSI/ASHRAE/IES
90A-1980 Standard.
Supplies required for installation:
• (10) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall
(minimum pull-out rating of 1,000 lbs.)
• 1/2" NPT hot and cold supply piping
• 1-1/2" NPT drain piping