beautypg.com

Wood’s Powr-Grip VL2MAN User Manual

Page 12

background image

Rev 1.0/12-12

10

VL2MAN: #35159

T

O

L

IFT AND

M

OVE THE

L

OAD

WARNING: Never attempt to lift load when lifter is in horizontal

orientation.

Controlling the Lifter and Load

When the red-line vacuum indicators show that the lifter is ready, use the hoisting equipment to

raise the lifter and load as needed to clear any obstacles in their path. Use the pad frame,
additional hand cups or other appropriate means to keep the lifter and load in the desired
orientation while they are suspended from the crane.

About Red-Line Indicators

Each hand cup is equipped with a red-line vacuum indicator. When the red-line indicators are

hidden on all the hand cups, the lifter is ready to lift the load.

WARNING: Never attempt to lift load when any red-line indicator is visible.

Do not attempt to lift a load while any red-line indicator is visible; such an attempt could result in

a load release and possible injury to the operator.

Monitoring Vacuum Indicators

All hand cups must remain visible to the operator, so that the red-line vacuum indicators can be

monitored throughout the entire lift. If any of the hand cups experiences leakage, its red-line
indicator becomes visible, to signal the reduction in vacuum to the operator.

WARNING: Monitor red-line indicators throughout entire lift; never leave

suspended loads unattended.

Check all red-line indicators frequently to make sure the vacuum pads are attached securely. If a

red-line indicator becomes visible while you are lifting a load, move away and stay clear of the
load until it can be lowered to the ground or a stable support.

WARNING: Stay clear of suspended load while any red-line indicator is visible.

Discontinue lifter use until the cause of the vacuum loss can be determined. If it is caused by

contamination, thoroughly clean the contact surfaces of the load and the vacuum pads (see

MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Cleaning), and reapply the lifter to the load. If a red-

line indicator remains visible when the lifter is attached to clean, smooth, nonporous materials,
the hand cup requires service or repair. Inspect the vacuum pad for damage (see
MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Inspection) and consult the hand cup instructions for

service directions. Perform inspection and maintenance as needed to identify and correct any
deficiency before resuming normal operation of the lifter.

T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

WARNING: Load must be fully supported before releasing vacuum pads.

When the load is at rest and fully supported, press the valve release lever (located opposite the

plunger) on each hand cup until all the vacuum pads disengage completely from the load.