beautypg.com

Maintenance, Nspection, Chedule – Wood’s Powr-Grip P11104DC2 User Manual

Page 27

background image

Rev 0.3/11-13

25

P1-DC2: #35112

MAINTENANCE

Make sure battery is disconnected before servicing lifter.

Note: Refer to

SERVICE MANUAL #36100

when applicable.

I

NSPECTION

S

CHEDULE

Perform inspections routinely, according to the following frequency schedule. If any deficiency is

detected, correct it before using the lifter (see

SERVICE MANUAL

when necessary) and perform

the next most frequent inspection.

Action

Every Lift Frequent

17

(20-40 hours)

Periodic

18

(250-400 hours)

Examine the vacuum pads for contamination or
debris, and clean them as necessary (see

V

ACUUM

P

AD

M

AINTENANCE

: Pad Cleaning).

X

X

X

Examine the vacuum pads for visual damage.

X

X

X

Examine the load surface for contamination or
debris, and clean it as necessary.

X

X

X

Examine the controls and indicators for visual

damage.

X

X

X

Test the battery for adequate charge. If
necessary, charge and retest the battery (see
B

ATTERY

R

ECHARGE

).

X

X

X

Examine the lifter’s structure for visual damage.

X

X

Examine the vacuum system (including vacuum
pads, fittings and hoses) for visual damage.

X

X

Examine the air filters for conditions requiring

service.

X

X

Perform the V

ACUUM

T

EST

.

X

X

Check for unusual vibrations or noises while
operating the lifter.

X

X

If the lifter is equipped with a Remote

Control System, perform the R

EMOTE

C

ONTROL

S

YSTEM

T

EST

.

X

X

17

The Frequent Inspection is also required whenever the lifter is out of service for 1 month or more.

18

The Periodic Inspection is also required whenever the lifter is out of service for 1 year or more. If necessary, return the lifter

to Wood’s Powr-Grip or an authorized dealer for repair (see LIMITED WARRANTY).

This manual is related to the following products: