P1-DC2: #35112
MAINTENANCE
Make sure battery is disconnected before servicing lifter.
Note: Refer to
SERVICE MANUAL #36100
when applicable.
I
NSPECTION
S
CHEDULE
Perform inspections routinely, according to the following frequency schedule. If any deficiency is
detected, correct it before using the lifter (see
SERVICE MANUAL
when necessary) and perform
the next most frequent inspection.
Action
Every Lift Frequent
17
(20-40 hours)
Periodic
18
(250-400 hours)
Examine the vacuum pads for contamination or
debris, and clean them as necessary (see
V
ACUUM
P
AD
M
AINTENANCE
: Pad Cleaning).
X
X
X
Examine the vacuum pads for visual damage.
X
X
X
Examine the load surface for contamination or
debris, and clean it as necessary.
X
X
X
Examine the controls and indicators for visual
damage.
X
X
X
Test the battery for adequate charge. If
necessary, charge and retest the battery (see
B
ATTERY
R
ECHARGE
).
X
X
X
Examine the lifter’s structure for visual damage.
X
X
Examine the vacuum system (including vacuum
pads, fittings and hoses) for visual damage.
X
X
Examine the air filters for conditions requiring
service.
X
X
Perform the V
ACUUM
T
EST
.
X
X
Check for unusual vibrations or noises while
operating the lifter.
X
X
If the lifter is equipped with a Remote
Control System, perform the R
EMOTE
C
ONTROL
S
YSTEM
T
EST
.
X
X
17
The Frequent Inspection is also required whenever the lifter is out of service for 1 month or more.
18
The Periodic Inspection is also required whenever the lifter is out of service for 1 year or more. If necessary, return the lifter