5.4 Line Identification

The IE-CT Mainframe recognizes up to nine different IE-CT Test Boxes. This feature allows the user to
run installation tests and line identifications at nine different lines in one operation.

Turn on the IE-CT and press the Step Key (H). The numeric display shows the Test Box number as a
flashing digit (B). If a flashing bar appears instead, the IE-CT Mainframe did not recognize the number
of the IE-CT Test Box.

5.5 Selection of Contact Assignment

Not all installations use shielded 8 conductor cables. Therefore the IE-CT Mainframe offers the
possibility to separate unused contacts for the test. Contact assignment can be adjusted with the
Selection Switches (C).

Adjust the nine Selection Switches after removing the protective cover. Switch 1 to 8 stand for
conductors 1 to 8, switch 9 stands for the shield of the termination.

Note
Make sure that at least one conductor with an even and one with an odd number are selected,
i. e. conductor 4 and conductor 5.

Selection Switches 1 to 9

Switch set “ON” means the
corresponding wire has been
connected.

&

After the last error is displayed a flashing digit is
shown in the numeric display (B). This digit stands
for the number of the connected Test Box.

'

If you press the Step Key (H) again as long as the Test Box number is flashing, the error list is
shown a second time, see item

!

.

(

For repeated testing continue as described under item

%

.

The IE-CT Mainframe can be turned off at any time by pressing the Start Key.