Specifications, Technology, Standards – Weidmuller IE-MC-VL Series - Industrial Ethernet Media Converters User Manual
Page 13: Ieee802.3, 802.3u, link fault pass-through, Interface, Rj45 ports, 10/100baset(x), Fiber ports, 100basefx (sc, st connectors available), Led indicators

Specifications
Technology
Standards
IEEE802.3, 802.3u, Link Fault Pass-Through
Interface
RJ45 ports
10/100BaseT(X)
Fiber ports
100BaseFX (SC, ST connectors available)
LED Indicators
Power, Fault, 10/100M, Full Duplex/Collision
Dip Switch
Port break alarm mask, 100BaseFx Full/Half
duplex selection
Alarm Contact
One relay output with current carrying capacity of
1A @ 24 VDC
Optical Fiber
Multi
mode
Single
mode, 40
Distance, km
5 40
Wavelength, nm
1310 1310
Min. TX Output, dBm
-20 -5
Max. TX Output, dBm
-14 0
Sensitivity, dBm
-34 to -30
-36 to -32
Recommended Diameter
62.5/125 9/125
(Core/Cladding) μm (1
dB/km,
800 MHz
× km)
Power
Input Voltage
24 VDC (12 to 45 VDC); Redundant inputs
Input Current (@24V)
0.16 A
Connection
Removable Terminal Block
Overload Current Protection 1.1 A
Reverse Polarity Protection Present
Mechanical
Casing
IP30 protection, aluminum case
Dimensions (W x H x D)
53.6 x 135 x 105 mm
Weight
0.63 kg
Installation DIN-Rail,
Wall
Mounting
Environmental
Operating Temperature
0 to 60°C (32 to 140
o
F),
Storage Temperature
-40 to 85°C (-40 to 185
o
F)
Ambient Relative Humidity 5 to 90% (non-condensing)
Regulatory Approvals
Safety
UL60950, UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C and
D
ATEX Class I, Zone 2, EEx nC IIC
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), level 3
- 13 -