beautypg.com

Dip switch setting, Ie-mc-vl series dip switch, Dip switch 1 (default: off ) – Weidmuller IE-MC-VL Series - Industrial Ethernet Media Converters User Manual

Page 11: Dip switch 2 (default: on ), On: enables full duplex for 100basefx, Off: disables full duplex for 100basefx, Dip switch 3, Reserved for future use, Led indicators

background image

Dip Switch Setting

IE-MC-VL Series DIP switch

1

2

3

ON DIP

Dip Switch 1 (Default: Off )
ON: Enables the PORT Alarm. If the port’s link fails, the

relay will form an open circuit and the fault LED will
light up.

Off: Disables the corresponding PORT Alarm. The relay

will form a closed circuit and the Fault LED will
never light up.

Dip Switch 2 (Default: ON )
ON: Enables full duplex for 100BaseFX
Off: Disables full duplex for 100BaseFX
Dip Switch 3
Reserved for future use

To activate the updated DIP switch setting, power off and then power on the
Media Converter.

LED Indicators

The front panel of the Media Converter contains several LED indicators. The
function of each LED is described in the table below.

LED

Color

State

Description

On

Power is being supplied to power

input PWR1

PWR1

AMBER

Off

Power is not being supplied to

power input PWR1

On

Power is being supplied to power

input PWR2

PWR2

AMBER

Off

Power is not being supplied to

power input PWR2

On

When the corresponding PORT

alarm is enabled, and the port’s

link is inactive.

FAULT

RED

Off

When the corresponding PORT

alarm is enabled and the port’s link

is active, or when the

corresponding PORT alarm is

disabled.

On

TP port’s 10 Mbps link is active

Blinking

Data is being transmitted at 10

Mbps

10M

GREEN

Off

TP Port’s 10 Mbps link is inactive

On

TP port’s 100 Mbps link is active

Blinking

Data is being transmitted at 100

Mbps

100M

(TP)

GREEN

Off

100BaseTX Port’s link is inactive

- 11 -