Rated data

Input

Range

Maximum ratings

Field device excitation

Other input specification

Other input specification

Output

Range

Load

Burnout level

Zero / Span adjustment

Protection

Other output specification

Other output specification

Supply

Range

Consumption

Other supply specification

General

Accuracy

Linearity

Temperature coefficient (drift)

Transmission frequency

Response time. 90% span

Other general specification

Status LED

Isolation (# of ports)

Operating / Storage temperature

Housing (mounting)

Dimensions (Lx W x H)

Wire range (conductor size)

Insulation stripping length

Tightening torque

Approvals

Ordering data

Ultra SlimPak

Heat sink (width)

Shunt resistor

RTD temperature sensor, 3 wire

-200 to 850°C for Pt100/Pt500/Pt1000, -200 to 260°C for Cu10/Cu100

-80 to 320°C for Ni120, -200 to 240°C for NiFe604, DIP switch selectable

±5Vdc

<2mA for Pt100, Pt500, Pt1000, Ni120, Cu100 or NiFe604; <10mA for Cu10

leadwire resistance: 40% of base sensor resistance or 100

M (whichever is less), maximum per lead.

leadwire effect: less than 1% of selected span over entire leadwire resistance range.

2 form C relays (2 SPDT), one set point per relay, gold flash/silver alloy

2 set points independently adjustable over 100% of the selected input span, HI or LO, failsafe or non-failsafe

maximum 5A at 120Vac, 2A at 240Vac, 5A at 28Vdc (resistive load), minimum 10

HA at 10mV

deadband adjustable from 1% to 5% of span

external relay contact protection required for inductive load switching

Electrical life: 10

5

operations at rated load

Mechanical life: 10

7

operations no load

DC voltage

9 to 30Vdc, inverter isolated

1.5W typ., 2.5W max. (300mA inrush at 9Vdc).

0.2% of full scale

±0.05% of full scale/°C, max.

<250mS in normal mode, dynamic deadband: relay status will change when proper setpoint/process

condition exists for 100mS

input green (>110% of input: 8Hz, <-10% of input: 4Hz), 2 setpoint red (ON: tripped, OFF: safe)

1800V (3 port) between contacts, input and power

-15°C to 55°C / -25°C to 75°C

EG12 (TS32 and TS35)

90mm x 17.7mm x 112.7mm max.

22-12AWG (0.5-4.0mm

2

)

7mm

0.4-0.8Nm

CSA (file LR-42272), UL (file E99775), CE marked (EMC dir. 89/336/EEC, LV dir. 73/23/EEC)

Cat. No.

G118 (factory calibration: 0-250ºC (Pt 100), A-HI/B-LO, non-failsafe)

HS01-A (1.6mm) (conditionally required depending on installation, see heat sink data)

Note: G118-000X where X is the revision level. For 2 wire sensors: connect RTN and - externally

Specifications subject to change without notice. 99990014 - 8/98 Printed in Canada

RTD

RTD Return

RTD Input (+)

RTD Input (+)
RTD Return

TS32 RAIL

TS35 RAIL