beautypg.com

Tempzone™ twin important installation information – WarmlyYours TempZone Twin Important User Manual

Page 2

background image

Installation Support • No Nonsense™ Warranty • (800) 875-5285 • www.WarmlyYours.com

TempZone™ Twin

Important Installation Information

10060-C 2/2012

IMPORTANT: BEFORE STARTING YOUR FLOOR WARMING PROJECT, PLEASE REVIEW

THESE IMPORTANT INSTALLATION INSTRUCTIONS.

NEVER cut the blue warming cable*

NEVER shorten the warming roll*

NEVER connect TWO (2) warming rolls together in series, always wire in parallel

NEVER fold or position the warming system so that the mesh overlaps itself or other warming

cables (this could lead to dangerous overheating)

NEVER run a power lead or sensor wire across the blue warming cable

NEVER place built-in cabinets or furniture with solid, or enclosed bases on top of the heated
area of the floor

(this could lead to dangerous overheating)

NEVER when laying the system on top of a concrete subfloor, lay the warming cable over

an expansion joint

NEVER run a warming cable in or through a wall

NEVER lay the warming system closer than 2” from a wall or heat source

NEVER connect the warming roll to the power supply before it is installed beneath the floor

covering (this could lead to dangerous overheating)

NEVER operate the system until the mortar has had time to cure

*Cutting the warming cable or shortening the roll will:

1. Cause the installed warming system to overheat,

2. Take your installation out of compliance with the NEC (National Electrical Code) and UL
(Underwriters Laboratories), and

3. Require a correction effort that will cost you time and money. CAREFULLY CHECK YOUR
FLOOR PLAN NOW; CALL WARMLYYOURS at (800) 875-5285 if you need a different
length roll shipped overnight.

Note: You can cut and shorten the 15’ cold lead wire coming out of the warming roll.