MODEL QTR140L

5. Connect electrical wiring.

Run 120 VAc house wiring to installation location. Use

proper Ul approved connector to secure house wiring to

wiring plate. connect wires as shown in wiring diagrams.

CONNECT WIRING

3. Attach

damper/duct
connector.

Snap damper /

duct connector

onto housing.

make sure con-

nector is flush with

top of housing and

damper flap falls

closed. If using

4-inch ductwork,

install 6” to 4” duct reducer over duct connector.

4. Install

6-inch or 4-
inch round
ductwork.

connect 6-inch

or 4-inch round

ductwork to

damper / duct

connector or

reducer. Run

ductwork to a

roof cap or wall cap. Tape all ductwork connections to

make them secure and air tight.

INSTALL HOUSING & DUCT

1. Bend

housing
tabs.

Use a pliers to

bend housing

TABS out to 90

0

.

2. Mount

housing to
joist.

Hold housing

in place so that

the housing tabs

contact the bottom

of the joist. The

housing mounts

with four (4)

screws or nails.

SpAcER

(use for mounting to I-Joist)

I-JoIST

TABS

INSTALL GRILLE

6. Finish ceiling.

Install ceiling material. cut out around housing.

7. Attach grille

to housing.

Squeeze grille

springs and insert

them into slots

on each side of

housing.

Screw or nail housing to joist through lowest holes in each

mounting flange, then through highest holes. NOTE:

mounting to I-JOIST (shown) requires use of SPACERS

(included) between the highest hole of each mounting

flange and the I-joist.