For more information – Vicor MegaMod DC-DC Converter Family User Manual
Page 8
Output Wire Gauge.
Use the output wire gauge that
corresponds to the output current of your converter, below:
105 A–160 A : #4
26 A–40 A : #10
7 A–10 A : #16
66 A–104 A : #6
16 A–25 A : #12
4 A–6 A : #18
41 A–65 A : #8
11 A–15 A : #14
0 A–3 A : #20
Output Voltage Trimming.
Do not trim the outputs higher than
110% of their nominal output voltage. When an output is
trimmed up, do not exceed its maximum rated output power.
Operating Temperature.
Do not allow the baseplate of the
module to exceed 85°C for MegaMods or 100°C for MegaMod
Jr.’s. The mounting interface area should be flat within 0.005",
free of burrs, and coated with thermal compound (Wakefield
Engineering Type 120 or equivalent, or a thermal pad).
Depending on the power level and ambient temperature,
additional cooling measures may be required. Note: For
configurations using three 12 V input (75 W) or 24 V input
(150 W) modules and operating at ambient temperatures
in excess of 50°C, please consult Vicor’s Applications
Engineering Department.
For More Information
The Vicor Applications Manual and product data sheets contain
complete information about MegaMods and MegaMod Jr.’s.
To receive literature or to consult an applications engineer about
installation or operation of these products, contact your nearest
Vicor office. (See page 8.) Vicor’s Applications Manual is also
available on-line at: vicorpower.com
(Bitte lesen Sie die Sicherheits-Vorschriften auf Seite 8.)
“AMP” and “Faston” are registered trademarks of AMP, Incorporated, Harrisburg, PA.
7