Pecifications – Vicor VIPAC 28 Vdc MIL-COTS User Manual

Page 7

background image

6

v i c o r p o w e r . c o m

28 Vdc Input MIL-COTS Version

Parameter Min Typ Max Unit Notes

Operating input voltage 18 28 36 Vdc Continuous
Turn-on 18 Vdc
Inrush current 5.0 A pk
Inrush limiting 0.007 A µF
Transient immunity (M-FIAM5B) 50 Vdc 12.5 ms per MIL-STD-704E/F
Transient immunity (M-FIAM9) 100 Vdc 50 ms per MIL-STD-1275A/B/D

250 Vdc 70 ms per MIL-STD-1275A/B/D
70 Vdc 20 ms per MIL-STD-704A
50 Vdc 12.5 ms per MIL-STD-704E/F

EMI MIL-STD-461E Conducted emissions: CE101, CE102

Conducted susceptibility: CS101, CS114, CS115, CS116

Reverse Polarity Protection Internally fused

Parameter Min Typ Max Unit Notes

Dielectric withstand

Input to chassis 1,500 / 2,121 Vrms / Vdc

Operating chassis temperature
H-Grade -40 95 °C
M-Grade -55 95 °C

Shock

MIL-STD-810F

Method 516.5, Procedure 1

(40 g for 15–23 ms, 75 g for 8–13 ms)

Vibration MIL-STD-810F Method 514.5, Procedure 1 (20–2000 Hz at 5 g)
Humidity 5 95 % Non-condensing

Parameter Min Typ Max Unit Notes

Output voltage set point ±1 % Vout nom
Line regulation ±0.02 ±0.2 % Low line to high line; full load
Temperature regulation ±0.002 ±0.005 %/˚C Over operating temp. range
Over temperature shut down

115 ˚C

Power sharing accuracy ±2 ±5 % 10% to 100% of full load
Programming range 10 110 % Of nominal output voltage.

(For trimming below 90% of nominal, a minimum load

of 10% of maximum rated power may be required)

Current limit 115 % Iout max. Output voltage 95% of nominal
Short circuit current 115 % Iout max. Output voltage <250 mV

S

PECIFICATIONS

Output Specifications - General

at 25°C, nominal line and nominal load, per module unless otherwise specified

Output Sequencing

Power up will always occur in the defined sequence stored within the device. Any preprogrammed

power down sequence, except the default, will not be in effect upon loss or removal of the VIPAC

source voltage. Sequenced power down can only be achieved by issuing the requisite commands

through the interface before removing the source voltage.

Environmental

Type Master Output Output Bus Emergency

Enable Enable / Disable Sequencing OK Off

Local

√ √ √

Ρεμοτε √ √ √ √ √

Interface Control Functions