MAINTENANCE

VALVE REPLACEMENT

1) Shut off the gas supply.

2) Remove the louvers (and bay door if installed).

3) Open

the

fl ush door and remove the door.

4) Remove the logs and brick panels.

5) Remove the grate by loosening the two screws and sliding the grate

out.

Grate screws

6) Remove the burner assembly by removing the 2 screws and lifting

it out.

7) Remove the 2 screws holding the Air Intake Hood to the rear fi rebox

wall and lift out.

8) Disconnect the inlet gas line.

9) Disconnect the EV1, EV2, and ground wires from the valve - as shown

below.

11) Push the valve assembly to the left and lift the entrire assembly out.

12) Replace with new valve tray assembly and reverse steps 10 - 1.

10) Remove the 11 screws securing the valve tray in place - then lift the

entire assembly out.

EV1

EV2

Ground