beautypg.com

Installation, Contemporary faceplate and doorframe installation – Regency Energy U32E Medium Gas Insert User Manual

Page 21

background image

U32E-5 FPI Direct Vent Gas Insert

21

INSTALLATION

3)

Position faceplate on unit lining up screw holes on faceplate with

screw holes on unit - secure with 4 screws.

Note: Ensure that the fl anges on the sides of the fi rebox are on the
outside, when installing the faceplate (see below).

Faceplate

Flange on fi rebox

1)

Bring the faceplate up in front of the unit and connect the red &
black ON/OFF wires from the unit to the ON/OFF switch on the
back of the left side of the faceplate.

2)

Connect the grey coated female ends of the black & red fan wires
from the unit to the male ends of the fan rheostat on the left side of
the faceplate as shown.

Fan Rheostat

Metal Lip

Openings on hinge

4)

Fold down the 2 hinges on the bottom frame to a fl at position.

The bottom frame is installed with a friction fi t - the opening in the
corner of each hinge slides over the metal lip located on the fl oor of
the unit.


Note

: Ensure the bottom frame is positioned properly before

installing, by making sure there is equal spacing on either side.

5)

Push both bottom frame hinges down on the metal lip until

they are fully seated.

6)

Flip bottom louver up to close.

Kit# 425-914 Contents List:

1

Complete Faceplate with Switches

1 Door

Frame

1 Bottom

Louver

2 Hinges
2 Bottom Louver Brackets
4

Pan Head Screws

1 Wire

Clip

1 Instruction

Sheet

CONTEMPORARY FACEPLATE AND DOORFRAME INSTALLATION