MAINTENANCE

Annual Maintenance

Completely clean out entire unit

Annually

Inspect air tubes, baffl es and bricks

Replace any damaged parts.

Adjust door catch / latch

If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust latch after new gasket installed.

Inspect condition and seal of:
Glass Gasket
Door Gasket

Perform paper test - replace gasket if required

Paper Test

Test the seal on the loading door with a paper bill.
Place a paper bill in the gasketed area of the door on a cold stove–close
the door.
Try to remove the paper by pulling.
The paper should not pull out easily, if it does, try adjusting the door latch,
if that doesn't solve the problem replace the door gasket.

Check and lubricate door hinge + latch

Use only high temperature anti seize lube. (ie. never seize)

Check glass for cracks

Replace if required.

Clean blower motor

Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*

Inspect and clean chimney

Annual professional chimney cleaning recommended.