Hampton H300 Cast Freestanding Woodstove

INSTALLATION

MINIMUM ALCOVE CLEARANCE TO

COMBUSTIBLE MATERIALS

This Hampton Freestanding model has been alcove approved and must be installed
with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height (from fi nished fl oor) - 60" (1525 mm)

Maximum depth of alcove - 48" (1220 mm)

From From Flue Min. Min.Hearth

Unit (with Heat Shield)

Unit

Center-line Width to Rear Wall

G H

I J K L

H300

15" (381 mm) 13" (330 mm) 28" (711 mm) 13" (330 mm) 57" (1448 mm) 51-1/4"

without side load door

(1301 mm)

ADDITIONAL CLEARANCES

FOR BACKWALL EXIT

Note: Floor Protection must extend 2" (50mm)

to each side of the elbow.

Note: If side load door is used, fl oor protection

must extend at least 18" (457mm) from
the side of the unit.

Minimum Clearance to Non-Combustibles

From

Unit (with Heat Shield)

Unit

A B

H300

min. 0" (0 mm) 15" (381mm)

max. 9" (228 mm)

60" (1524 mm)

with side load door

Minimum Clearance to Combustibles

From

Unit (with Heat Shield)

Unit

A B

H300

9" (228 mm) 15" (381 mm)

Min. Mantel Height (from fi nished fl oor):

48" 1219 mm

Max. Mantel Depth:

12" 305 mm