beautypg.com

Installation, Brick installation – Regency Classic F5100 Extra Large Wood Stove User Manual

Page 19

background image

F5100 Regency Freestanding Woodstove

19

INSTALLATION

5

4

2

2

3

1

BRICK INSTALLATION

Firebrick is included to extend the life of your stove and radiate heat more evenly. Install all fi rebricks per the diagram below and place in their correct positions.
Do not use a grate.

1. Remove box of fi rebricks from inside unit.

2. Remove Lyotherm sheet from mailer tube and install on base of fi rebox as shown below.

NOTE: The "AD" brick covers the Ash Dump hole that is used when the Ash Drawer Kit is installed.

Lyotherm sheet

Final Install

3. Order of fi rebrick install:

a) Rear Firebrick

b) Firebox fl oor - install brick over Lyothern Sheet

c) Right and left side Firebricks

Fire bricks

#

Size

1

4-1/2" x 9"

2

2" x 9"

3

3-1/2" x 4-1/2"

4

1-3/4" x 4-1/2"

5

2" x 7"

AD brick