Installation – Regency Classic F5100 Extra Large Wood Stove User Manual

Page 12

background image

12

F5100 Regency Freestanding Woodstove

INSTALLATION

8

8

8

8

FLOOR PROTECTION

A combustible fl oor must be protected by non-combustible
material (like tile, concrete board, or certifi ed to UL-1618 or
as defi ned by local codes) extending beneath the heater and
a minimum of 8" (203mm) from each side and minimum 16"
(406mm) from the front face of the stove and minimum 6"
(or the rear clearance to combustibles whichever is smaller)
from the rear of the stove.

When installed with horizontal venting, non-combustible fl oor
protection must beneath the fl ue pipe and extend 2" (51mm)
beyond each side.

Minimum Overall Width (X) of Floor
Protector
for all installations:

Stove

F5100

45" (1143 mm)

NOTE: In Canada, fl oor protection must extend 18" (450mm) to the front

and 8" (203mm) to each side and back of the stove.

Minimum Overall Depth (Y) of Floor Protector

Unit

Residential

Close Clearance

Mobile Home

Close Clearance

Alcove

F5100

Y

Z

Y

Z

Y

Z

USA

49-1/8"

8"

49-1/8"

8"

49-1/8"

8"

Canada

53-1/8"

8"

53-1/8" 8"

53-1/8"

8"

The rear clearance to combustibles is less than 6" (for corner installations the rear corners may
be angled to take advantage of the closer clearances.