Informations, Informations informationen – Sulky VISION 1 DPB User Manual
Page 49

49
Informations
E
Informations
Informationen
Faults - Solutions
Faults
Solutions
The unit does not lit up
Check
- unit/power supply connections
- fuses supply line
Flow rate test
Check
- calibration factor
- shutters are closed
Repeat the fixed station trial.
Shutters open to maximum then to minimum
Check
- Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)
The unit lits up but the rams do not move
Check
- Fuses
Area counter reading incorrect
Check
- connection / machine
- working width
- drive rate
Flow rate
Check
- programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate
- shutter opening/closing performance
- ram travel
- peg marking
The drive rate is incorrect
Check
- connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity
(100Ω ± 10)
- 100-m coefficient
Tonnage counter reading incorrect
Check
- connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing
GB