Schwank supremeSchwank IO-210 User Manual
Page 20

2300 / IO 210 Manual
IM110107
RD: MAY 2014
R.L. 15A
20
MODEL
Voltage
VAC
Current
amps
Btu/hr input
Total
Weight (lbs).
Length
< A >
2312 / IO 212 -NG
2312 / IO 212 -LP
2313 / IO 213 -NG
2313 / IO 213 -LP
24
40 VA*
23,000
23,000
35,000
35,000
32
32
44
44
30 1/2”
30 1/2”
43 1/2”
43 1/2”
14. HEATER DIMENSIONS & CONFIGURATIONS
Figure 5: DIMENSIONS
Front View
End View
Table 5: CAPACITIES & CONFIGURATIONS
* For a multiple heater installation, the first heater is sized at 40VA and each consecutive
heater is sized at 20VA. The sum total will be the required Transformer size. If total VA
exceeds one transformer size select the next higher VA rated transformer.
15. MOUNTING KIT OPTIONS (NOTE: For unusual mounting application contact
manufacturer.)
ITEM NO
PART NUMBER
DESCRIPTION
1
JP-2300-MB
WALL MOUNTING BRACKET
2
JP-2300-MK
ARM MOUNTING BRACKET
3
JP-2300-PK
POST BRACKET
The heater is supplied with chain mounting bracket JP-2300-HS
Other optional mounting kits are available:
WARNING: Wall Mounting Bracket JP-2300-MB, or Arm Mounting Bracket JP-2300-MK:
Ensure that anchoring to the structure is of sufficient strength, integrity and
workmanship, to adequately support the weight of the heater and any other
potential loads such as snow build up.
A
10”
13”