Start up, Introducing incoming power, Red black co detector – RKI Instruments 65-2335RK User Manual
Page 11: Cable shield controller housing, J-box

65-2335RK CO Transmitter • 7
Figure 4: Wiring the CO Transmitter to a Controller
12. If shielded cable is used, connect the cable’s drain wire to an available chassis (earth)
ground at the controller. RKI controllers typically have a ground stud that can be used
to ground the cable’s drain wire.
Start Up
This section describes procedures to start up the CO transmitter and place the transmitter
into normal operation.
Introducing Incoming Power
1.
Complete the installation procedures described earlier in this manual.
2.
Verify that the power wiring to the controller is correct and secure. Refer to the
controller operator’s manual.
3.
Turn on power to the controller.
4.
Turn on the controller.
5.
Verify that the controller is on and operating properly. Refer to the controller
operator’s manual.
SI
G
/P
W
R
S
SPA
N
ZE
R
O
Red
Black
CO Detector
+
S
Controller Detector/Transmitter
Terminals, Typical Designations
Cable Shield
Controller Housing
T
O
X
IC
O
X
Y
J-Box