beautypg.com

Set units, Setup fuel type, Standby – PLX Devices Kiwi MPG User Manual

Page 7: Restore to factory defaults, Technical specifications, 7 standby, 8 restore to factory defaults, 9 technical specifications, 4 set units, 5 setup fuel type

background image

www.plxkiwi.com

(408)745-7591

7

6.4 Set Units

This mode allows you to set the unit of measurement.


0 - Mode 1 (Gallons, Miles, MPG, Dollars, MPH, Fahrenheit)
*default
1 - Mode 2 (Liters, Kilometers, Km/L, Dollars, kmh, Celsius)
2 - Mode 3 (Liters, Kilometers, L-100Km, Dollars, kmh,

Celsius)

6.5 Setup Fuel Type

This mode allows you to set the fuel type.


0 - Gasoline (14.7) *default
1 - Diesel (14.6)
2 - E85 (9.86)
3 – Ethanol (9.0)

4 – Methanol (6.4)
5 – CNG (17.2)
6 – LPG (15.5)

7 Standby

When your vehicle is turned off, the Kiwi MPG automatically

saves your trip information and goes into a standby mode
leaving one blinking light on. When your vehicle is started up,
the Kiwi MPG automatically starts and resumes in the menu
where it left off.

*In some vehicles, due to ECU incompatibility, the automatic
standby detection may not work correctly. If the unit does not
automatically go into standby, press and hold BOTH buttons
for 3 seconds to save your trip information. If the unit does
not resume from standby after the vehicle has started, turn
the power switch off and then back on to reconnect.

8 Restore to Factory Defaults

To restore your unit back to factory default settings, press and hold both buttons during power on.

9 Technical Specifications

Physical Dimensions

1 x 2.5 x 0.5 inches

Compatible Fuels

Gasoline, Diesel, Ethanol, E85, CNG, Methanol, LPG

Power Consumption

< 1 Watt

OBDII/CAN Protocols

ISO-9141, VPW, PWM, KWP 2000, 11Bit CAN, 29Bit CAN

C

ompatible Vehicles

1996 and later Vehicles

Operation Temperature

-40 - 105 Deg C

Operating Voltage

10V-18V

Human Interface

2 Button

Enclosure

Automotive Grade Plastic