Troubleshooting – PLX Devices Legion Gen2 11,000 mAh User Manual
Page 11

PLX
devices inc.
www.plxdevices.com
11
5
Troubleshooting
Resetting Legion
Problem Charging Your Device
If Legion has an error or freezes, you may need to reset Legion to regain functionality.
Quick Reset
For a quick product reset, unplug and replug the jumper from the jumper port. Th is will restart the product and
retain any ongoing data (such as remaining capacity of the battery and charge cycles).
Factory Setting Reset
To reset the product to its factory setting:
1. Remove the jumper from the jumper port (See Figure 1).
2. Press and hold down the button, and plug the jumper back in to the jumper port. You should see the
following screen:
If Legion is unable to charge your device:
1. Check to see if your device can be charged with a diff erent power source using the same cable. If your
device is not charging, the cable or the device itself might be the source of the problem.
2. If the device is charging normally with a diff erent power source, connect Legion to the device using the
same cable, and make sure Legion is turned ON. Legion is unable to charge devices while OFF.
NOTE: Legion can charge devices while in Sleep Mode.
3. If Legion is unable to turn ON or if the voltage reading is less than 3.4 V, recharge Legion’s battery. Legion
is unable to charge devices if the battery voltage is too low.
3. Remove the jumper from the jumper port once again.
4. Plug the jumper back in to the jumper port, and Legion should reset to factory conditions.
5. It is recommended to put Legion through one full charge cycle (fully charging the battery, fully draining
the battery, and fully charging once more) before further use. Allowing Legion to execute one full charge
cycle will permit Legion to calibrate itself for accurate subsequent readings.
NOTE: Performing a Factory Setting Reset will permanently reset the charge cycles value. However, the
charge cycles value has no infl uence on the other functions of the product. It is the only data value that
will be inaccurate if the product is functioning properly aft er a Factory Setting Reset.