3.2.1.4
SW6, SW7, SW8 - Link Modes
These three DIP-switches configure the link mode settings. DIP-switch SW6 is valid when Port 1 is set to
“AN” or “MAN”. DIP-switches SW7 and SW8 are ignored when Port 1 is set to “AN”. The following
table details possible Link Mode DIP-switch configurations.
PI
SA
SW1
SW6
SW7
SW8
Result
Left
(AN)
Left
Left
Left
Enables Link Segment mode (LS).
Left
(AN)
Right
Left
Left
Enables Link Propagate mode (LP).
Right
(MAN)
Left
Left
Left
Enables Link Segment mode (LS).
Right
(MAN)
Right
Left
Left
Enables Link Propagate mode (LP).
Right
(MAN)
Left
Right
Left
Enables Remote Fault Detection
mode plus Link Segment mode
(RFD+LS).
Right
(MAN)
Right
Right
Left
Enables Remote Fault Detection
mode plus Link Propagation mode
(RFD+LP).
Right
(MAN)
Left
Left
Right
Enables Symmetrical Fault Detect
mode (SFD).
Right
(MAN)
Right
Left
Right
Illegal Setting, Link Segment (LS) is
selected.
Right
(MAN)
Left
Right
Right
Illegal Setting, Link Segment (LS) is
selected.
Right
(MAN)
Right
Right
Right
Illegal Setting, Link Segment (LS) is
selected.
SW1
SW6
SW7
SW8
Result
Down
(AN)
Down
Down
Down
Enables Link Segment mode (LS).
Down
(AN)
Up
Down
Down
Enables Link Propagate mode (LP).
Up
(MAN)
Down
Down
Down
Enables Link Segment mode (LS).
Up
(MAN)
Up
Down
Down
Enables Link Propagate mode (LP).
Up
(MAN)
Down
Up
Down
Enables Remote Fault Detection
mode plus Link Segment mode
(RFD+LS).
Up
(MAN)
Up
Up
Down
Enables Remote Fault Detection
mode plus Link Propagation mode
(RFD+LP).
Up
(MAN)
Down
Down
Up
Enables Symmetrical Fault Detect
mode (SFD).
Up
(MAN)
Up
Down
Up
Illegal Setting, Link Segment (LS) is
selected.
Up
(MAN)
Down
Up
Up
llegal Setting, Link Segment (LS) is
selected.
Up
(MAN)
Up
Up
Up
llegal Setting, Link Segment (LS) is
selected.
NOTE: Connecting two converters together where both are set to any of the RFD modes is illegal
and will cause a “deadly embrace” lockup.
NOTE: It is recommended to keep the LS setting (default) until initial configuration is complete.
For detailed information on the operation of the different Link Modes, download the application note
“iConverter Link Modes” available on Omnitron’s web page:
http://www.omnitron-systems.com/downloads.php
3.3
INSTALLING THE MODULE AND CONNECTING CABLES
PI
a.
Carefully slide the module into an open slot in the chassis. Align the module with the installation
guides and ensure that the module is firmly seated against the backplane. Secure the module by fastening
the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front. Verify the
“Pwr” LED is ON (indicating the chassis is powered).
SA
a.
The Gx AN standalone media converter is available in tabletop and wall-mounting models. For wall-
mounting, attach the Gx AN to a wall, backboard or other flat surfaces. For tabletop installation, place
the unit on a flat and level surface. Attach the rubber feet to the bottom of the Gx AN to prevent the
unit from sliding. Make sure the unit is placed in a safe, dry and secure location.