Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which flow constantly (non-inter-
mittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5-2
Operating current
Ambient temperature
➀ wire gauge: 1.5 mm²
➁ wire gauge: 2.5 mm²
➂ wire gauge: 4 mm²
Technical characteristics
Specifications
DIN EN 60 664-1
DIN EN 61 984
Monoblocks
Electrical data
acc. to EN 61 984
16 A 500 V 6 kV 3
Rated current
16 A
Rated voltage
500 V
Rated impulse voltage
6 kV
Pollution degree
3
Pollution degree 2 also
16 A 690 V 8 kV 2
Insulation resistance
≥ 10
10
Ω
Material
polycarbonate
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V 0
Mechanical working life
- mating cycles
≥ 500
Contacts
Material
copper alloy
Surface
- hard-silver plated
3 µm Ag
- hard-gold plated
2 µm Au over 3 µm Ni
Contact resistance
≤ 2 mΩ
Crimp terminal
- Wire gauge
0.14 ... 4 mm²
- AWG
26 ... 12
Stripping length
6.5 mm
Tools
see chapter 99