Utl series, Assembly instruction, Technical information – Northern Connectors Souriau UTL Series Push-Pull Connectors User Manual
Page 33: Utl stripping dimensions, Assembly
33
© 2012 – SOURIAU
• 1 - Female insulator: Strip external cable sheath, adjust ground cable length
• 2 - Male insulator: Strip external cable sheath, adjust signal cable lengths
• 3 - Crimp contacts
• 4 - Place the lubrifi cant on the contact orings
• 5 - Place all the contacts inside the corresponding cavities in the same time
• 6 - Manually push each contact, or use specifi c tools, until audible click.
Check each contact rétention, with a traction with two fi ngers
UTL stripping dimensions
* see page 31
UTL0103G1P - UTL6103G1P -
UTL7103G1P - UTL1103G1P
UTL0103G1S - UTL6103G1S -
UTL7103G1S - UTL1103G1S
Ground contact must be different compared to the others.
L*
L*
30.1mm
32.1mm
Phase lines - male contacts
Phase lines - male contacts
Ground line -
female contact
Ground line - female contact
25mm
25mm
Assembly instruction
UTL Series
Technical information
• Strip wires, crimp contacts
• Insert contacts into connector cavities (insert manually or use tool RTM2
0
5 crimp contacts)
• Place receptacle in the panel cut-out (see dimension page 15)
• Secure receptacle with M3 screws (not supplied), torque 0.7 N.m maxi
Panel
Panel
Receptacle fl ange
Pa
Pa
UTL
0
assembly
(mounting suggestion)
T
echnical information