beautypg.com

Generator start-up procedure (manual) – Multiquip DCA125SSIU User Manual

Page 34

background image

PAGE 34 — DCA125SSIU 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #3 (01/13/11)

GENERATOR START-UP PROCEDURE (MANUAL)

BEFORE STARTING

1. Place

the

main, G.F.C.I., and aux. circuit breakers (Figure

35) in the OFF position prior to starting the engine.

Figure 35. Main, Aux. and GFCI

Circuit Breakers (OFF)

2. Make sure the voltage change-over board has been

confi gured for the desired output voltage.

3. Connect the load to the receptacles or the output

terminal lugs as shown in Figure 10. These load
connection points can be found on the output terminal
panel and the output terminal panel’s hard wire hookup
panel.

4. Tighten terminal nuts securely to prevent load wires

from slipping out.

5. Close all engine enclosure doors (Figure 36).

Figure 36. Engine Enclosure Doors

CAUTION

The engine’s exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating.
Direct exhaust away from nearby personnel.

WARNING

NEVER manually start the engine with the main, GFCI
or auxiliary
circuit breakers in the ON (closed) position.

INCORRECT

CORRECT

STARTING (MANUAL)

1. Place the engine speed switch (Figure 37) in the LOW

(down) position.

Figure 37. Engine Speed Switch (Low)

2. Place

the

MPEC control switch in the MANUAL

position to start the engine (Figure 38).

Figure 38. MPEC Control Switch

(Manual Position)

3. Depending on the temperature of the coolant (cold

weather conditions), the pre-heat lamp (Figure 39) will
light (ON) and remain on until the pre-heating cycle has
been completed. After completion of the pre-heating
cycle, the light will go OFF and the engine will start up
automatically.

Figure 39. Pre-Heat Lamp

4. Once the engine starts, let the engine run for 1-2

minutes. Listen for any abnormal noises. If any
abnormalities exist, shut down the engine and correct
the problem. If the engine is running smoothly, place
the engine speed switch (Figure 40) in the HIGH (up)
position.

Figure 40. Engine Speed Switch (High)

5. Verify that the engine running

status LED on the MPEC unit
(Figure 41) is ON (lit) after the
engine has been started.

Figure 41. Engine Running LED (ON)