Checking Trowel arm Straightness

Trowel arms can be damaged by rough handling, (such as

dropping the trowel on the pad), or by striking exposed

plumbing, forms, or rebar while in operation. A bent trowel

arm will not allow the trowel to operate in a smooth fluid

rotation. If bent trowel arms are suspect, check for flatness

as follows, refer to Figure 31 and Figure 32.

Figure 31. Trowel Arm

1. Use a thick steel plate, granite slab or any surface

which is true and flat, to check all six sides of each

trowel arm for flatness.

2. Check each of the six sides of the trowel arm (hex section).

A feeler gauge of .004" (0.10 mm) should not pass

between the flat of the trowel arm and the test surface

along its length on the test surface. (Figure 32) .

Figure 32. Checking Trowel Arm Flatness

3. Next, check the clearance between the round shaft and

the test surface as one of the flat hex sections of the

arm rests on the test surface. Rotate the arm to each

of the flat hex sections and check the clearance of the

round shaft. Use a feeler gauge of .005" (0.127 mm).

Each section should have the same clearance between

the round of the trowel arm shaft and the test surface.

4. If the trowel arm is found to be uneven or bent, replace

the trowel arm.

Trowel Arm

Round Shaft Section

Trowel Arm

Hexagonal (Hex)

Shaft Section

Lever Mounting Slot

(Left Arm Shown)

Roll Pin

Hole

Blade

Attachment

Bolt Hole

(One of Three)

Flat of

Hexagonal

Shaft

(Top of Arm)

Trowel

Arm

Flat Test

Surface

Feeler Gauge

(.004 in. / 0.10 mm)

Feeler Gauge

(.005 in. / 0.127 mm)

Trowel arm adjustment

1. Locate the trowel arm adjustment tool (Figure 33) P/N

9177.

Figure 33. Trowel Arm Adjustment Tool

(Side View)

2. Ensure the fixture arm is in the proper setting (up or down)

for your trowel arm rotation as shown in Figure 34.

Figure 34. Trowel Arm Adjustment Setup

Adjustment

Bolt

“Distance”

Locking

Nut

Fixture

Arm

NOTICE

Arms with

clock-wise blade rotation use the fixture arm

in the UP position (A in Figure 34). Arms with

counter

clock-wise blade rotation use the fixture with the fixture

arm in the DOWN position. (B in Figure 34).

A