PAGE 26 — MAYCO LS300 CONCRETE PUMP • OPERATION AND PARTS MANUAL — REV. #4 (06/21/10)
SET-UP
LOCATION OF PUMP
1. Place the pump in the best location on the site to pump
concrete efficiently.
2. Lay down the hose in the shortest distance possible.
REAR STABILIZER JACKS
To reduce excessive vibration and rocking of the pump, set
the rear stabilizers as follows:
1. Locate both the left and right rear stabilizer jacks
(Figure 15).
2. Remove the
cotter pin from the handle tee bolt eye,
and then
pull the handle tee to release the stabilizer
jack (Figure 16).
3. Position both rear stabilizers jacks on firm (not loose)
level ground (Figure 17).
4. Align the hole on the stabilizer jack with the hole on the
frame body and
insert handle tee bolt.
5. Insert the cotter pin into handle tee bolt eye to lock the
stabilizer jack.
Figure 15. Locating Rear Stabilizer Jacks
Figure 17. Rear Stabilizer Stand Deployment
Figure 16. Rear Stabilizer Jack
NEVER place feet under jack while operating.
ALWAYS retract rear stabilizer jacks prior to towing.
ALWAYS retract rear stabilizer jacks prior to servicing to
relieve load (working pressure).
WARNING - REAR STABILIZER SAFETY