beautypg.com

Digital control panel components – Multiquip LS-300 User Manual

Page 20

background image

PAGE 20 — MAYCO LS300 CONCRETE PUMP • OPERATION AND PARTS MANUAL — REV. #4 (06/21/10)

DIGITAL CONTROL PANEL COMPONENTS

Figure 6. Pump Digital Control Panel Components

1.

Emergency Stop Button – Press emergency stop
button to stop pump in an emergency. Turn knob
counterclockwise to disengage the stop button.

2.

Ignition Switch – Insert the ignition key here to start
the engine. Turn the key clockwise to the ON position,
then continue turning clockwise to the START position
and release. To stop the engine turn the key fully
counterclockwise to the STOP position.

3.

Digital Readout Screen – Displays and monitors the
various functions of the machine.

4.

Scroll Switch – Allows the operator to scroll the various
readout screens.

5.

Reset Switch – Allows the operator to reset the stroke
counter.

6.

Remote Cable Connector – Insert the remote control
input cable into this connector.

7.

Direction Control Switch – This 2-position switch
controls the direction of flow for any mix in the pump.
The

leftmost position sets the pumping direction to

forward and the

rightmost position sets the pumping

direction to reverse.

8.

Pumping Control Switch – This 3-position switch
controls the pumping of the pump. The

rightmost

position (REMOTE) is for use with the remote control
unit, the

leftmost position (LOCAL) is for normal

pumping operation, and the

centermost position

(CENTER OFF) prevents pumping.

9.

Cylinder Stroke Control Switch This 2-position
switch controls the pumping function. The

leftmost

position (AUTOMATIC) sets the pump to

automatic

cycling. Set the switch to this position for normal pump
operation.

The

rightmost position (JOG) changes the pump from

automatic to

manual cycling. This allows the cylinders

to be manually cycled using the

Manual Cylinder

Jogging Switch.

10. Manual Cylinder Jogging Switch – This 2-position

switch allows the operator to manually jog the cylinders
to assist in clearing material line packs and is used to
test pumping pressure (See

Initial Start-up Procedure

section of this manual for testing procedure).

The

leftmost position jogs Cylinder “A” and the

rightmost position jogs Cylinder “B”.

13. Main Pressure Gauge This gauge monitors the

system pressure while pumping material. The maximum
pressure rating is 3100 PSI ± 50.