Nsf/ansi 42 - aesthetic effects, Xv. performance data sheet – Purenex Multipure Aquaperform For Model MP880SB User Manual
Page 24

N
OTES:
1.
Multi-Pure Drinking Water Systems have been certified, as indicated, by NSF International for compliance to NSF/ANSI Standard Nos. 42 & 53.
2. The Multi-Pure Drinking Water Systems have been certified by the State of California Department of Public Health for the reduction of specific
contaminants listed herein.
3. Chloroform was used as a surrogate for claims of reduction of VOCs. Multi-Pure Systems tested at >99.8% actual reduction of Chloroform. Percent
reduction shown herein reflects the allowable claims for VOCs as per tables in the Standard.
4. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
5. Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. For optimum performance, it is
essential that the filter be replaced on a regularly scheduled basis as follows: (a) annually; (b) when the unit’s rated capacity has been reached; (c)
the flow rate diminishes; (d) the filter becomes saturated with bad tastes and odors.
6. Model No. MP880EL includes a capacity monitor that automatically flashes a yellow light when it is time to replace your filter.
7. Multi-Pure Drinking Water System STAINLESS STEEL Housings are warranted for a lifetime (provided that filter has been changed at least once per
year). All exterior hoses and attachments to the System are warranted for one year. Please see the Owner’s Manual for complete product
guarantee and warranty information.
8. Please see the Owner’s Manual for installation instructions and operating procedures.
9.
In compliance with New York law, it is recommended that before purchasing a water treatment system, NY residents have their water supply tested
to determine their actual water treatment needs. Please compare the capabilities of the Multi-Pure unit with your actual water treatment needs.
10. Check for compliance with state and local laws and regulations.
11.
While testing was performed under standard laboratory conditions, actual performance may vary.
12. The list of substances which the treatment device reduces does not necessarily mean that these substances are present in your tap water.
Operational Specifications
MP880SB
MP880SI
MP880EL
Approximate Service Capacity (6)
600 Gallons
600 Gallons
960 Gallons
Replacement Filter Type Model No./ Approx. Cost
CB11AS/$110
CB11AS/$110
CB11AS/$110
Approximate Flow Rate @ 60 psi
1.0 gpm
1.0 gpm
1.0 gpm
Maximum Water Pressure
100 ps i/7.03 kg/cm 2
100 ps i/7.03 kg/cm 2
100 ps i/7.03 kg/cm 2
Minimum Water Pressure
30 psi/2.1 kg/cm2
30 psi/2.1 kg/cm2
30 psi/2.1 kg/cm2
Maximum Operating Temperature
100°F/38°C
for cold water use
100°F/38°C
for cold water use only
100°F/38°C
for cold water use only
Minimum Operating Temperature
32°F/0°C
32°F/0°C
32°F/0°C
Substance
Percent
Reduction**
Influent challenge
concentration
(m g/L unless specified)
Maximum permissible
product water
concentration
(m g/L unless specified)
CHLORAMINE as Aesthetic Effect (As
Monochloramine)
>97%
3.0 mg/L +/- 10%
0.5 mg/L
CHLORINE as Aesthetic Effect
99%
2.0 Mg/L +/- 10%
> or = 50%
PARTICULATE, (Nominal Particulate Reduction, Class
I, Particles 0.5 TO <1 UM
Class I > 99%
At Least 10,000 particles/mL
> or = 85%
NSF/ANSI 42 - Aesthetic Effects
The System has been tested according to NSF/ANSI Standard 42 for the reduction of the following substances. The con-
centration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system.
Note: This addresses the U.S. Environmental Protection Agency (EPA) Primary and Secondary Drinking Water Regulations in effect at its time of publica-
tion, they relate to Multi-Pure’s performance in conformance to the industry performance criteria. These regulations are continually being updated at the
Federal level. Accordingly, this list of MCLs will be reviewed and amended when appropriate. Please see sales brochure for list of product certifications.
24
MP880SB / MP880EL
MP880SI
MP880EL faucet
with capacity
monitor
MP880SB faucet
XV.
Performance Data Sheet
(continued)