Installation of Venting System Components














WARNING

Refer to the Bradford White EverHot TG series water heater Installation and Operation Instruction
Manual for details concerning vent system termination positions/clearances, allowable vent pipe
lengths, and in what position dip switch number 1 should be placed. If you do not understand how to
configure your vent pipe system and/or which position dip switch number 1 should be placed in,
please contact your Bradford White supplier for assistance.

WARNING

All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the
venting system installation to prevent any possible leakage into the room. Make sure all the pipe
connections are firmly pressed together so that the gaskets form a tight seal.

NOTICE

When mounting the water heater on an outside wall, be sure the vent/air intake pipe will exit
between the wall studs. DO NOT cut through the wall studs for the vent/air intake pipe opening.


CAUTION

Failure to properly support the vent piping with hangers and clamps may result in damage to the
water heater or venting system.

Vertical venting must be supported every 5 feet of vertical run and horizontal venting must be
supported every 3 feet of horizontal run of vent pipe length.

WARNING

Before installation inspect each vent component for damage and correct seal placement. Do not
attempt to fix or install any damaged vent components.




When installing the EverHot

TG model series direct vent water heaters, use only EverHot vent/air

intake system kits and components. Installation and service must be performed by a qualified
installer, service agency, or the gas supplier. Installation must meet all state and local codes
regarding installation and location of vent systems for direct vent appliances. In the absence of
local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas
and Propane Installation Code must be followed. The maximum vent length, as stated in the in this
manual, should never be exceeded. Follow the instructions below and all instructions located in
this manual when installing a vent pipe system. Improper installation of vent piping, or failure to
follow all installation instructions completely, can result in property damage, and/or death.