36" Coverage
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
2' 3' 4' 5' 6' 7' 2' 3' 4' 5' 6' 7'
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
36"
80
36"
50
36"
50
26
Ga.
24
22
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
0.89
1.15
1.48
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
Inward
Load
Outward
Load
0.0187 0.0349 0.0130 0.0308
209 94 48 25 14 9 313 142 80 52 36 26
0.0273 0.0524 0.0190 0.0482
272 123 70 36 21 13 392 178 101 65 45 33
0.0367 0.0741 0.0267 0.0676
379 172 95 49 28 18 551 251 142 91 64 47
1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are
effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and applicable
testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or
fasteners/support connection and panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
Slope
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
ATTACHMENT DETAIL
FASTENING PATTERN
The minimum recommended slope for PBU-Panel is 1:12.
Metal Sales recommends that in all roof applications
sealants be used on all sidelaps with stitch screw 1'-0" on
center.
PBU-Panel is designed to be utilized over open structural
framing, but can easily be used with a solid substrate. To
avoid panel distortion, use a properly aligned and uniform
substructure.
PBU-Panel are available in 3/4" rib height with a coverage
width of 36".
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging, shipping, and
erection. Please consult Metal Sales for recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary loading
and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Acrylic Coated Galvalume
®
, MS Colorfast45
®
,
or various Kynar 500 (PVDF) colors.
Gauges: 26 ga and 24 ga standard, 22 ga optional
1
/
4
"-14 x
7
/
8
" Stitch Screw
(for roof only)
Tape Sealant
(for roof only)
#12-14 x 1
1
/
4
" Self Driller
1
/
4
"-14 x
7
/
8
" Stitch Screw
(for roof only)
Tape Sealant (for roof only)
#12-14 x 1
1
/
4
" Self Driller