PDR-8

DELTA RIB

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

D

esign

/ i

nsTallaTion

C

onsiDeraTions

(

ConT

.)

FASTENING PATTERN

Typical Screw Fastening Pattern

Typical Nail Fastening Pattern

Tape Sealant

(roof only)

1

/

4

"-14 x

7

/

8

" Stitch Screw

(1'-0" o.c.)

#10 x 1" Woodscrew

Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and

uniform substructure.

The installer should check the roof deck for squareness before installing Delta Rib Panels. Several methods can be used to verify

squareness of the structure for proper installation of the panels.

METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from

similar points at the ridge and eave and obtain the same dimension.

METHOD "B" - The 3-4-5 triangle system may also be used. To use this system measure a point from the corner along the edge

of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4). Then by

measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square

corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the

roof system cannot be installed as shown in these instructions.

CONDITION OF SUBSTRUCTURE

METHOD A

METHOD B

4

30

30

3

5

Note: Fastening patterns should be checked to meet applicable loading conditions.