beautypg.com

3 adjustment options, Ich 500, Light – Memmert IPS Peltier-cooled incubators User Manual

Page 25

background image

D24034 | Date 10/2014

25

Operation and control

3. Save the set value by pressing the confir-

mation key.

The display returns to normal and the

appliance begins adjusting to the defined

set value.

Hauptschalter

>

Zu der Typenbezeichnung gibt es momentan drei Entwurfsrichtungen,

ich kann Ihnen noch nicht sagen, ob Memmert hierzu schon eine Entscheidung

getroffen hat.

Die hier gezeigt Variante, ist die von uns empfohlene Richtung.

UF 110

PLUS

ON

344

.4

444

4

.

TEMP

Set

°C

°C

FLAP

40

%

TIMER

h

d

10

02

End

Sept.

29

22 24

FAN

%

0

%

100

ALARM

max

444

.4°C

auto

+/-

0.0

K

min

444

.4°C

O

O

ON

N

N

N

O

O

N

O

Manu

44.Sept

°C

22

.4

TEMP

°C

Set 37.0

If no new values are entered or confirmed for approx. 30 seconds, the appliance automati-

cally restores the former values.
If you want to cancel the setting procedure, press the

activation key on the left or right of the display that you

want to exit. The appliance restores the former values.

Only the settings that you have confirmed by pressing the

confirmation key before cancelling the setting procedure

are accepted.

5.4.3 Adjustment options

As described in chapter 5.4.2 , you can set the following parameters after pressing the cor-

responding activation key (in any sequence):
Temperature

Temperature

Adjustment range: model-dependent (see nameplate and technical

data on page 13)

Heating operation is indicated by the symbol.

symbol.

Cooling is indicated by the symbol.
You can select °C or °F as the temperature unit displayed (see

page 34).

°C

22

.4

TEMP

°C

Set 37.0

The minimum temperature that can be reached depends on the surrounding conditions.

The appliances reach up to to 25 °C below room temperature. In order to do so, the

Peltier module needs sufficient ventilation (see Fig. 7 on page 18).

Interior lighting (only for cooled incubators IPP with light module)

Interior lighting (only for cooled incubators IPP with light module)
Adjustment range: 0 % (off), 100 % (on)

LIGHT

%

100

5.4.4 Operation with digital backwards counter with target time setting,

adjustable from 1 minute to 99 days (Timer)

In timer operation, you can adjust the time the appliance runs at the set temperature.

1. Press the activation key to the left of

the timer display. The timer display is

activated.

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

.5°C

100

ICH 500

MENU

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

MENU

TIMER

-

Ende 9:00 23.11.

--

h

-

m

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

.5°C

100

ICH 500

MENU

30.0

%rh

50.0

%CO

2

Programm 12

Fr 20.10.2010

20:31

min

000°C

max

000°C

MENU

22

.4°C

TEMP

37

.0

°C

Set

This manual is related to the following products: