Menu mode

7.3.6 Remote control

In the setup entry

Remote control

, you can set whether

the appliance should be controlled via remote control and if

so, in which mode. These settings are available:

Off

Read Only

Write

Write+Alarm

When the appliance is in remote control mode, the

symbol appears in the temperature display. In the

symbol appears in the temperature display. In the

settings

Write

and

Write+Alarm

, the appliance cannot be

controlled at the ControlCOCKPIT until the remote control

has been switched off (setting Off) or set to

Read Only

.

In order to use the remote control function, program-

ming skills and special libraries are required.

7.3.7 Gateway

The setup entry

Gateway

is used to connect two networks

Gateway

Gateway

with different protocols.
The gateway is set the same way as the IP address (see page

32).

7.4 Date and Time

In the

Time

display, you can set date and time, time zone and daylight saving time.

Always set the time zone (and summer time yes/no) before you set the date and time.

Avoid changing the set time after that since this can lead to gaps or overlapping when

recording measured values. If you still need to change the time, you should not run a

programme immediately before or after doing so.

1. Activate the time setting. To do so, press

the activation key on the right side of

the

Time

display. The display is enlarged

and the first adjustment option (

Date

)

automatically highlighted.

UFP 100

Date and time

Time
Time zone
Daylight savings

12

.

05

.

2012

12:00
GMT +1

SETUP

SOUND

CALIBRATION

LANGUAGE

SETUP

SOUND

CALIBRATION

LANGUAGE

Date

2. Turn the turn control until

Time zone

is

highlighted.

Hauptschalter

>

Zu der Typenbezeichnung gibt es momentan drei Entwurfsrichtungen,

ich kann Ihnen noch nicht sagen, ob Memmert hierzu schon eine Entscheidung

getroffen hat.

Die hier gezeigt Variante, ist die von uns empfohlene Richtung.

UF 110

PLUS

ON

344

.4

444

4

.

TEMP

Set

°C

°C

FLAP

40

%

TIMER

h

d

10

02

End

Sept.

29

22 24

FAN

%

0

%

100

ALARM

max

444

.4°C

auto

+/-

0.0

K

min

444

.4°C

O

O

ON

N

N

N

O

O

N

O

Manu

44.Sept

TIME

Time

Daylight savings

12.05.2012
12:00
GMT

+1

Date

Time zone

Setup

Balance

Remote Control

Off

Gateway 192.168.5 .1

+30 %

2/2

23

.2°C

TEMP

Set 180

.0°C

Setup

Balance

Remote Control Off

Gateway

192.168.5 .1

+30 %

2/2

This manual is related to the following products: