beautypg.com

M ag .l ay e r s, Mechanical – Mag Layers USA SMB-403025 User Manual

Page 4

background image

MECHANICAL

TEST ITEM

TEST DETAILS

Humidity

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test

resistance

Insulation resistance and DC resistance on

circuit board,the test shall be done.

the specification(refer to clause 2-1)

Measurement : After placing for 24 hours min.

shall be met.

Temperature : +60

±2℃ , Humidity : 90 to 95 %RH

The terminal electrode and the ferrite must

Applied voltage : Rated voltage

not damaged.

Applied current : Rated current

Testing time : 500

±12 hours

Thermal

Impedance:Within

±20% of the initial value.

shock

Insulation resistance and DC resistance on

the specification(refer to clause 2-1)

shall be met.

The terminal electrode and the ferrite must

not damaged.

Low

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test

temperature Insulation resistance and DC resistance on

circuit board,the test shall be done.

storage

the specification(refer to clause 2-1)

Measurement : After placing for 24 hours min.

shall be met.

Temperature : -40

±2℃

The terminal electrode and the ferrite must

Testing time : 500

±12 hours

not damaged.

Vibration

Impedance:Within

±20% of the initial value.

After the samples shall be soldered onto the test

Insulation resistance and DC resistance on

circuit board,the test shall be done.

the specification(refer to clause 2-1)

Frequency : 10 to 55 Hz

shall be met.

Amplitude : 1.52 mm

The terminal electrode and the ferrite must

Dimension and times : X ,Y and Z directions

not damaged.

for 2 hours each.

Solderability New solder More than 75%

Flux (rosin, isopropyl alcohol{JIS-K-1522})

shall be coated over the whole of the sample

before hard, the sample shall then be preheated

for about 2 minutes in a temperature of

130~150℃ and after it has been immersed to a

depth 0.5mm below for 3

±0.2 seconds fully in

molten solder M705 with a temperature of 245

±2℃.

shall be couered with new solder smoothly when

the sample is taken out of the solder bath.

Page 4/6

SMB-403025

SPECIFICATION

M AG .L AY E R S