(4) RELIABILITY TEST METHOD
MECHANICAL
TEST ITEM
SPECIFICATION
TEST DETAILS
Humidity
Impedance:Within
±20% of the initial value.
After the samples shall be soldered onto the test circuit
resistance
Insulation resistance and DC resistance on the
board,the test shall be done.
specification(refer to clause 2-1) shall be met.
Measurement : After placing for 24 hours min.
The terminal electrode and the ferrite must not
Temperature : +60
±2℃ , Humidity : 90 to 95 %RH
damaged.
Applied voltage : Rated voltage
Applied current : Rated current
Testing time : 500
±12 hours
Thermal shock
Impedance:Within
±20% of the initial value.
Insulation resistance and DC resistance on the
specification(refer to clause 2-1) shall be met.
The terminal electrode and the ferrite must
not damaged.
Low
Impedance:Within
±20% of the initial value.
After the samples shall be soldered onto the test
temperature
Insulation resistance and DC resistance on the
circuit board,the test shall be done.
storage
specification(refer to clause 2-1) shall be met.
Measurement : After placing for 24 hours min.
The terminal electrode and the ferrite must
Temperature : -40
±2℃
not damaged.
Testing time : 500
±12 hours
Vibration
Impedance:Within
±20% of the initial value.
After the samples shall be soldered onto the test circuit
Insulation resistance and DC resistance on
board,the test shall be done.
the specification(refer to clause 2-1)
Frequency : 10 to 55 Hz
shall be met.
Amplitude : 1.52 mm
The terminal electrode and the ferrite must
Dimension and times : X ,Y and Z directions
not damaged.
for 2 hours each.
Solderability
New solder More than 75%
Flux (rosin, isopropyl alcohol{JIS-K-1522}) shall be coated
over the whole of the sample before hard, the sample shall
then be preheated for about 2 minutes in a temperature
of 130~150℃ and after it has been immersed to a depth
0.5mm below for 3
±0.2 seconds fully in molten solder
M705 with a temperature of 245
±5℃. More than 75% of the
electrode sections shall be couered
with new solder smoothly when the sample is taken out
of the solder bath.