ENVIROMENT CHARACTERISTICS
TEST ITEM
SPECIFICATION
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in an atmospere with
storage
a temperature of 125℃ and a normal humidity.
There shall be
Upon completion of the measurement shall be made after the
sample has been left in a normal temperature and normal
damage.
humidity for 1 hour.
Low temperature
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in an atmosphere with
storage
a temperature of -25
±3℃.
There shall be
Upon completion of the test, the measurement shall be made
no mechanical
after the sample has been left in a normal temperature and
damage.
normal humidity for 1 hour.
Change of
△L/Lo≦
±5%
The sample shall be subject to 5 continuos cycles, such as shown
temperature
in the table 2 below and then it shall be subjected to standard
There shall be
atmospheric conditions for 1 hour, after which measurement
no other dama-
shall be made.
ge of problems
table 2
Temperature
Duration
-25
±3℃
(Themostat No.1)
Standard
atmospheric
(Themostat No.2)
Standard
atmospheric
Moisture storage
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in a temperature of
40
±2℃ and a humidity(RH) of 90~95%.
There shall be
Upon completion of the test, the measurement shall be made
no mechanical
after the sample has been left in a normal temperature and
damage.
normal humidity more than 1 hour.
Test conditions:
The sample shall be reflow soldered onto the printed circuit board in every test.
Page-5/8
MSI-280904CP-SERIES-
□-□□
No.1→No.2
No.2→No.1
1
2
3
4
30 min.
30 min.